Field Calibration (On-site Calibration)

Field calibration (on-site calibration) is conducted in the actual operational environment, providing a more accurate reflection of the instrument’s performance during its use. It also saves the time that would be spent to transport the instruments to a lab for calibration, ensuring that production and operational processes remain unaffected. This would meet the needs for your large-scale systems. Taiyi’s professional calibration team possesses extensive experiences and expertise in field calibration, we are equipped with precise calibration instruments and reference standards. Hence we can perform calibrations quickly and accurately, providing detailed calibration certificates & services to help you to fully understand your instrument’s condition and performance.

Length

Equipment Range
2D Height Gauge (0 to 330)mm
(0 to 600)mm
Yard Gauge / Meter Gauge 0 to 9999(m or yard)
Measuring Microscopes (0 to 300)mm
Two-dimensional image measuring instrument projector (0 to 600)mm
Platform 300 mm to 500 mm
600 mm to 800 mm
900 mm to 1100 mm
1200 mm to 2000 mm

Mass and Force

Equipment Range
*Electronic Balance Range / Resolution: up to 200 mg / 0.0001 mg
Range / Resolution: up to 5 g / 0.000001 g
Range / Resolution: up to 200 g / 0.00001 g
Range / Resolution: up to 200 g / 0.0001 g
Range / Resolution: up to 2 kg / 0.0001 g
Range / Resolution: up to 5 kg / 0.001 g
Range / Resolution: up to 15 kg / 0.01 g
Range / Resolution: up to 30 g / 0.01 g
Range / Resolution: up to 30 kg / 0.1 g
Electronic Scale *(up to 30) kg
(up to 300) kg、≦30 kg/Resolution>0.01 g
Moisture analyzer Range / Resolution: up to 100 g / 0.001g
Tensile testing machine Tension:(1 to 500) kgf
Compress testing machine
Burst strength tester
Universal material testing machine
Bend Test Machine
Spring testing machine
Load curve testing machine
Tension:(1 to 500) kgf
Compress:(1 to 5000) kgf

Pressure

Equipment Range
Pressure Gauge Pneumatic (0 to 70) kgf/cm2
    (0 to 1000) psi
    (0 to 69) bar
Hydraulic (0 to 700) kgf/cm2
    (0 to 10000) psi
    (0 to 690) bar
Digital Pressure Gauge
Pressure Transducer
Pressure Sensor
Pressure Converter
Pneumatic (0 to 70) kgf/cm2
    (0 to 1000) psi
    (0 to 69) bar
Hydraulic (0 to 700) kgf/cm2
    (0 to 10000) psi
    (0 to 690) bar
Differential Pressure Gauge
Differential Pressure Meter
(0 to 1980) Pa
(0 to 200) mmH2O

Temperature & Humidity

Equipment Range
Thermometer Temperature Comparison Calibration
(-30 to 600)℃
Symbol
(-30 to 200) ℃
Temperature Recorder Temperature Comparison Calibration
(-30 to 200)℃
Symbol(-30 to 200) ℃
Solder Pot
Temperature control unit
Precision Temperature control unit
<Requirements ± (0.01~0.05)°C>
Temperature Comparison Calibration
(-50 to 500)℃
Hot plate
Temperature Curve
Temperature Comparison Calibration
(-50 to 400)℃
Furnace
Accelerated Weathering Tester
Aging Oven
Temperature Comparison Calibration
(-100 to 1200)℃
Temperature Curve
Melt Flow Index Tester
Temperature Comparison Calibration
(-100 to 1000)℃
Liquid Nitrogen Container Temperature Comparison Calibration
-196 ℃
Highly Accelerated Stress Testing Chamber(HAST) Temperature and Humidity Comparison Calibration
(-30 to 145)℃、(10 to 100)%RH
Autoclave
Autoclave(1 cycle,F0 Value in Steam Sterilization)
Autoclave(3 cycle,F0 Value in Steam Sterilization)
Temperature Curve(Autoclave)
Temperature Comparison Calibration
(-20 to 135)℃
Autoclave Temperature Comparison Calibration
(-20 to 135)℃
Temperature control unit Temperature Comparison Calibration
(-95 to 1200)℃
Special Temperature control unit Temperature Comparison Calibration
(-95 to 1000)℃
Oven Temperature Comparison Calibration
(-100 to 1000)℃
Burn In Room
Temperature Curve
Refrigerator
freezer
Incubator
Temperature Comparison Calibration
(-100 to 300)℃
Oven(Special Positions)
Thermo Shock Tester
Temperature Comparison Calibration
(-100 to 1000)℃
Circulating Water Baths
Dry Bath
PCR
Tunnel Oven
Temperature Comparison Calibration
(-100 to 500)℃
Temperature & Humidity Controlled Chamber
Walk-in Temperature and Humidity Chamber
Temperature and Humidity Comparison Calibration
(-100 to 250)℃
(1 to 98)%RH@(10 to 98)℃
Dry Cabinet Temperature and Humidity Comparison Calibration
(10 to 50)℃、(10 to 98)%RH
(1 to 10)%RH,(※Contact us。)
Temperature & Humidity Comparison(Single Point) Temperature and Humidity Comparison Calibration
(10 to 50)℃、Depending on the site environment  
Temperature & Humidity Comparison(Points can be specified) Temperature and Humidity Comparison Calibration
(18 to 35)℃、(30 to 80)%RH
(Above 31°C, up to 75% RH)
Temperature & Humidity Curve Humidity Comparison
(10 to 98)%RH
Large Salt Spray Test Chamber(Chamber-like square box) Temperature and Humidity Comparison Calibration
(-100 to 250)℃
(10 to 98)%RH
Temperature Indicator
Temperature Recorder
Salt Spray Tester
Reflow Tracker
Standard Temperature
(-270 to 1820)℃
Temperature & Humidity Chamber Standard Temperature and Humidity
(-100 to 1000)℃
(0 to 100)%RH
Indicator Standard signal conversion in various units
(4 to 20)Ma
(0 to 10)V

Electrical

Equipment Range
Meter
Voltmeter(Fingertip included)
Ammeter(Fingertip included)
DC Voltage    1 mV to 1 kV
AC Voltage    10 mV to 1 kV,60 Hz
DC Current    1 mA to 10 A
AC current    1 mA to 10 A,60 Hz
Digital multimeter(3~4½ digits)
Digital multimeter(5~6½ digits)
DC Voltage    1 mV to 1 kV
AC Voltage    10 mV to 1 kV,60 Hz
DC Current    100 uA to 10 A
AC current    100 uA to 10 A,60 Hz
Ohm            1 to 100 MΩ
Voltage source DC Voltage   1 mV to 1 kV
AC Voltage   10 mV to 1 kV,60 Hz
Current source DC Current    10 uA to 100 A
AC current 100 uA to 100 A,60 Hz
Recorder
Data Acquisition, Data Logger
DC Voltage    1 mV to 1 kV
DC Current   1 mA to 10 A
Resistance meter 1 Ω to 100 MΩ 
MicroOhm meter 0.1 mΩ、1 mΩ、10 mΩ 、100 mΩ
1 to 100 MΩ
High Resistance Meter、Insulation Tester 1 MΩ to 1 GΩ
10 V to 1 kV
Conductivity Meter (Signal Simulator) Full range MΩ.cm and full range μS/cm
(Resistance range: 10 Ω to 10 MΩ)
DC Power Supply DC Voltage 1 mV to 1 kV
DC Current 10 mA to 100 A 
AC Power Supply AC Voltage 10 V to 600 V,60 Hz
AC current 0.5 A to 10 A,60 Hz
Frequency 50 Hz to 400 Hz
Electrostatic teste 10 kΩ to 100 MΩ  
AC Withstand Voltage Tester AC Voltage 10 V to 10 kV,60 Hz
AC current 0.5 mA to 20 mA,60 Hz
AC Hipot Insulation Tester AC Voltage 0.5 kV to 10 kV,60 Hz
AC current 0.5 mA to 20 mA,60 Hz
Insulation Resistance 1 MΩ to 1 GΩ
Insulation Voltage 100 V to 1000 V
AC/DC Withstanding Voltage Tester DC Voltage 0.5 kV to 10 kV
AC Voltage 0.5 kV to 10 kV,60Hz
DC Current 0.5 mA to 20 mA
AC current 0.5 mA to 20 mA,60Hz
AC/DC Hipot Insulation Tester
Electrical Safety Analyzers DC Voltage 0.5 kV to 10 kV
AC Voltage 0.5 kV to 10 kV,60Hz
DC Current 0.5 mA to 20 mA
AC current 0.5 mA to 20 mA,60Hz
Insulation Resistance 1 MΩ to 1 GΩ
Insulation Voltage 100 V to 1000 V
Grounding Current 1 A to 25 A,60 Hz
Transmitter, Converter 1 mV to 1 kV
1 mA to 10 A

Chemical

Equipment Range
Conductivity Meter Depend on the water quality of the on-site pipeline
Conductivity Meter (84、1413、12880) μS/cm
pH Meter 4、7、10 (Resolution of 0.1 or higher)
pH Electrical Simulation (1 to 14)

Time & Frequency

Equipment Range
Centrifuge, Vortex Mixer (Speed) 20 to 30000 RPM
Centrifuge, Vortex Mixer (Time, Temperature) max 15 min.

Field Calibration System

Equipment Range
Electronic Balance
Climatic Chamber
Material testing machine
Spark tester
耐高壓試驗機
Granite Platform
Projection System
Refrigerator
Thermo Shock Tester
Temperature Controlled Chamber
Temperature & Humidity Controlled Chamber
Oven
Furnace
 Contact us